FEATURES/BENEFITS • Multi-jet design allows for simplicity and accuracy with wide flow ranges, even in low flow applications • Magnetically driven, hermetically sealed register does not leak or fog and is completely separated from the water • Designed for long service life and maintenance-free operation, even under harsh conditions • Integral strainer that protects meter from particulate damage • Easy installation with included coupling adapters • Pulsed output proportional to flow allows for remote flow totalization APPLICATIONS • Irrigation • Cooling systems • Filtration systems • Water monitoring SPECIFICATIONS Service: Water. Wetted Materials: Body: Brass, polyethylene; Couplings: Brass; Measuring chamber: Polyethylene, ABS plastic, ferrite, acetal. Flow Range: See model chart. Accuracy: Transitional flow: ±5%; Nominal flow: ±2%. Temperature Limit: 104°F (40°C). Pressure Limit: 232 psi (16 bar). Pressure Drop: See service manual. Totalizing Display Maximum: See model chart. Output Signal: Pulse output with frequency proportional to flow rate. Pulse Options: 0.1 gal, 1 gal, 10 gal, 100 gal per pulse (1 L, 10 L, 100 L per pulse). Electrical Rating: 0.01 A @ 24 VAC/DC. Electrical Connections: Color-coded lead wires, 4.5´ (1.5 m) long. Mounting Orientation: Horizontal. Weight: See dimension chart.