- Fuzzy Operation - 2 patterns., max 20 segs (NP100) - 30 patterns., max 300 segs. (NP200) - Selection between Input (19 kinds) and Output (3 kinds) - Communicating response type set up by back light (NP200)
Suffix code
Model |
Code |
Information |
NP200- |
|
|
Programmable temperature controller 96(W) × 96(H) mm |
Control Type |
0 |
|
Universal Type (heating) |
1 |
|
Heating/cooling Type (synchronous control type) |
Option |
0 |
None (DI - 1 ~ DI - 3 standard) |
1 |
Communication function (RS485/422) |
2 |
Contact input(D.I) 4 contacts (DI-4~DI7) |
3 |
Communication(RS485/422)+ contact input 4 contacts (DI-4~DI7) |
|
Model |
Code |
Information |
NP100- |
|
|
Programmable temperature controller 96(W) × 96(H) mm |
Control type |
0 |
|
Universal type (heating) |
Option |
0 |
None |
1 |
Time Signal 2 contacts |
2 |
Communication function (RS485/422) |
3 |
Time Signal 2 contacts and communication (RS485/422) |
|
Specification
Model |
NP100 |
NP200 |
Appearance |
|
|
W × H × D (mm) |
96 × 96 × 100 (mm) |
Function |
• Retransmission output • Input correction • Auto/Manul output • Heating/Cooling Control |
• 2 Alarm output (Relay) |
• 2 Time signals (Transistor) |
|
• Constant-value control |
• 5 Inner signals |
• Zone PID |
• 5 Time signals |
|
Power voltage |
100 - 240 V a.c (50/60 ?) |
Power consumption |
Max. 10 VA (except communication) |
Input |
Multi input a) T.C : K,J,E,T,R,B,S,L,N,U,W,PLII, b) R.T.D : Pt100(KS/IEC), KPt100(KS) |
c) DC Voltage input : 1 to 5 V, -10 to 20 mV, 0 to 100 mV, |
d) DC Current input : 4 to 20 mA(Connect a 250 Ωresistor to the input terminals) |
|
Control output |
Universal-output : Relay, SSR, Current |
Control action |
P.I.D or ON/OFF |
Alarm |
2 Alarm output |
4 Alarm output |
Communication |
RS 485/422 (Optional) |
Setting |
By Up/Down key on the front |
Display |
PV / SV : Digital LED |
PV : Digital LED , SV : LCD Back light |
Setting and display accuracy |
0.1 % of F.S (Full Scale) |
Setting resolution |
1 or 0.1% (According to input range) |
Memory protection |
Semipermanent |
External control |
3 Alarm output (Run, Reset, Hold) |
4 Alarm output (Run, Reset, Step, Hold) |
Number of pattern |
2 |
30 |
Number of segment |
20 |
300 |
Number of pattern contact |
- |
30 |
Operation |
1 ~ 99 times or limitless |
Program inclination |
Hour, Minute |
Sampling cycle |
250 ms |
Insulation resistance |
500 V a.c 20 ? min. |
Dielectric strength |
2300 V a.c 50/60 ? for 1 minute (Between primary and secondary terminal & between primary and ground) |
Ambient temperature & humidity |
0 ~ 50 ?, 35 ~ 85 % R.H. |
|