Page View 5880 |
Product Information : |
|
Product Name: |
|
HY series - analog |
|
Product Category: |
|
เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
|
Product Sub-Category: |
|
21 Temperature Controller (General Type)
|
Brand: |
|
Hanyoung |
Product Type : |
|
สินค้า, ผลิตภัณฑ์
|
|
|
|
|
- Simple temperature set up - Proportioning control or ON/OFF control - Burn out (Output OFF when sensor disconnected) - Plug in type, (simple correcting, checking and exchanging)
Suffix code
[ HY-1000 / HY-2000 / HY-3000 ] |
Model |
Code |
Information |
HY- / AF- |
|
|
|
|
|
|
Standard Model HY-1000 / HY-2000 / HY-3000 / AF1 |
Adjusting action |
F |
|
|
|
|
|
2-Position Control(ON / OFF) |
P |
|
|
|
|
|
Proportional action |
Input |
K |
|
|
|
|
K (CA) |
J |
|
|
|
|
J (IC) |
R |
|
|
|
|
R (PR 13%) |
D |
|
|
|
|
Pt100 Ω (KS Standards) |
P |
|
|
|
|
Pt100 Ω (DIN Standards) |
V |
|
|
|
|
*1 - 5 V d.c |
C |
|
|
|
|
*4 - 20 mA d.c |
Control Output |
M |
|
|
|
Relay contact |
C |
|
|
|
*Current (4 - 20 mA d.c) |
S |
|
|
|
*SSR driving (Voltage Pulse 12 V d.c) |
Alarm Output or Operation |
N |
|
|
None |
O |
|
|
High Limit Operation Alarm Output |
P |
|
|
Low Limit Operation Alarm Output |
W |
|
|
High / Low Limit Operation Alarm Output |
Control action |
R |
|
Reverse action Control (for Heating Control) |
D |
|
Direct action Control (for Cooling Control) |
Range code |
|
Standard Range Code Number Selection |
* Non-display product does not have the feature |
Model |
Suffix Code |
Information |
HY- |
|
|
|
|
|
|
Analog indication temperature controller |
Dimension |
4500S |
|
|
|
|
|
96(W) × 96(H) |
5000 |
|
|
|
|
|
72(W) × 72(H) |
Adjusting action |
F |
|
|
|
|
ON/OFF control (2 position control) |
P |
|
|
|
|
Proportional control |
Input |
K |
|
|
|
K thermocouple |
J |
|
|
|
J thermocouple |
R |
|
|
|
R thermocouple |
D |
|
|
|
Resistance Temperature Detector(RTD) KPt100 Ω |
P |
|
|
|
Resistance Temperature Detector(RTD) Pt100 Ω(IEC) |
V |
|
|
|
1 - 5 V d.c |
C |
|
|
|
4 - 20 mA d.c |
Control Output |
M |
|
|
Relay Output |
C |
|
|
Current output (4 - 20 mA d.c) |
S |
|
|
S.S.R (12 V d.c Voltage pulse output) |
Control operation |
R |
|
Reverse action (Heating control) |
D |
|
Direct action (Cooling control) |
Range code |
|
Select the standard range code |
[ HY-1000 / HY-2000 / HY-3000 ] |
Model / Code No. |
HY-1000 |
HY-2000 / 3000 |
AF1 |
Input |
Temp. Range |
Input |
Temp. Range |
Input |
Temp. Range |
1 |
Pt |
-50 ~ 50 |
|
|
Pt |
-99 ~ 99 |
2 |
|
|
Pt |
-50 ~ 100 |
|
|
3 |
Pt |
0 ~ 100 |
|
|
Pt |
0 ~ 99 |
4 |
|
|
Pt, K, J |
0 ~ 100 |
Pt, K |
0 ~ 199 |
5 |
Pt, K |
0 ~ 200 |
Pt, K, J |
0 ~ 200 |
Pt, K |
0 ~ 299 |
6 |
Pt, K |
0 ~ 300 |
Pt, K, J |
0 ~ 300 |
Pt, K |
0 ~ 399 |
7 |
Pt, K |
0 ~ 400 |
Pt, K, J |
0 ~ 400 |
|
|
8 |
K |
0 ~ 600 |
K |
0 ~ 600 |
|
|
9 |
K |
0 ~ 800 |
K |
0 ~ 800 |
|
|
10 |
K |
0 ~ 1200 |
|
|
|
|
11 |
|
|
K |
0 ~ 1200 |
|
|
12 |
|
|
R |
0 ~ 1600 |
|
|
Model / Code No. |
HY-4500S |
HY-5000 |
Input |
Temp. Range |
Input |
Temp. Range |
1 |
Pt100 Ω |
-50 ~ 50 |
Pt100 Ω |
-50 ~ 50 |
3 |
Pt100 Ω |
-50 ~ 100 |
Pt100 Ω |
0 ~ 100 |
5 |
Pt100 Ω |
0 ~ 100 |
K, Pt100 Ω |
0 ~ 200 |
6 |
- |
- |
K, Pt100 Ω |
0 ~ 300 |
7 |
K, Pt100 Ω |
0 ~ 200 |
K, Pt100 Ω |
0 ~ 400 |
8 |
K, Pt100 Ω |
0 ~ 300 |
K |
0 ~ 600 |
9 |
K, J, Pt100 Ω |
0 ~ 400 |
K |
0 ~ 800 |
10 |
K |
0 ~ 600 |
K |
0 ~ 1200 |
11 |
K |
0 ~ 800 |
- |
- |
13 |
K |
0 ~ 1200 |
- |
- |
14 |
R |
0 ~ 1600 |
- |
- |
Specification
[ HY-1000 / HY-2000 / HY-3000 ] |
Model |
HY-1000 |
HY-2000 |
HY-3000 |
Appearance |
|
|
|
Power supply voltage |
110 V a.c / 220 V a.c 60 ? |
Permissible Voltage Fluctuation Range |
Rated Voltage ±10 % |
Consumption Power |
Approx. 3 VA max |
Input |
Thermocouple, Resistive |
Thermocouple, Resistive, DC Current, DC Voltage |
Adjusting Sensitivity |
±0.2 % (fixed) of Max. Range |
Control Method |
Time Proportional Control, ON/OFF Control |
Setting Method |
Analog Setting |
Display Method |
Non-Display |
Deviation Display |
Control Output |
Relay Output :Capacity 250 V a.c 3 A |
Relay Output : capacity 250 V a.c 3 A SSR Output : 12 V d.c Load Resistance : Above 800 Ω |
Setting Accuracy |
Within ± 2.0 % of Max. Range |
Display Accuracy |
HY-1000 : ±1.0 % (fixed) of Max. Range HY-2000 : ±2.0 % (fixed) of Max. Range |
±2.5 % (fixed) of Max. Range |
Proportional Band |
3 % of Max. Range (fixed) |
Proportional Cycle |
Relay Output : Approx. 20 sec, SSR Output : Approx. 2 sec |
External Input Resistance |
Thermocouple : Below 100 Ω, Resistive : Below 10 Ω Per 1 Wire (The Resistance of Each Wire Should be the Same.) |
Reset Range |
None |
Alarm Setting Range |
- |
Alarm Output Adjusting Sensitivity |
- |
Hysteresis |
Thermocouple : 1.2 ? (Below 600 ?), 2.4 ? (Above 600 ?)35 Resistive : 0.6 ? (Below 200 ?), 1.2 ? (Above 200 ?) |
Dielectric Strength |
2000 V a.c 60 ? for 1 Minute |
Relay Life Expectancy |
Mechanical : Above 10 Millions Times, Electrical : Above 100 Thousands Times (250 V a.c, 3 A Resistive Load) |
Operating Ambient Temperature/Humidity |
0 ~ 50 ?, 35 ~ 85 % R.H (Without Condensation) |
Weight |
HY-1000 : 358 g (Including Brackets) |
HY-2000, 3000 : 558 g (Including Brackets) |
Model |
HY-4500S |
HY-5000 |
Appearance |
|
|
Power supply voltage |
110 V a.c / 220 V a.c, 60 Hz |
Allowable voltage fluctuation |
±10 % of power supply voltage |
Power consumption |
Approx. Max 3 VA |
Input |
Thermocouple, Resistive, d.c Current, d.c Voltage (see Standard Range Code)(Built - in Burnout circuit) |
Adjusting Sensitivity |
±0.2%(fixed) of Max. Range |
Control Method |
Proportional Control, ON / OFF Control |
Setting Method |
Analog Setting |
Display Method |
Analog Display |
Control Output |
Relay output : Capacity 250 V a.c 3 A (Resistive Load) contact : 1c |
SSR Output : 12 V a.c (Constant Voltage Pulse) (Resistive Load : above 800 Ω) |
Current Output : 4 - 20 mA d.c (Resistive Load : below 600 Ω) |
|
Setting Accuracy |
2 % of Max. Range |
Display Accuracy |
±2.0 % of F.S ±1 digit |
Proportional Band |
1 ~ 10 % of Max. Range(variable) |
3 % of Max. Range(fixed) |
Proportional Cycle |
Relay Output : 20 ~ 30 sec / SSR Output : 2 ~ 4 sec |
Insulation Resistance |
20 ? min ( 500 V a.c mega) |
Dielectric Strength |
2000 V a.c 50 ~ 60 Hz for 1 minute |
Noise Immunity |
Squared wave noise(pulse width : 1000 μs) ±1 KV |
Vibration Resistance |
10 - 50 Hz (cycle for 1 minute), double amplitude : 0.75 mm, each X Y Z direction for 1 hour |
Shock Resistance |
300 ? |
Relay Life Expectancy |
Mechanical : 10 millions times, Electrical : 100 thousands times (250 V a.c, 3 A Resistive Load) |
Ambient Temperature/Humidity |
0 ~ 50 ? / 35 ~ 85 % R.H (without condensation) |
Weight |
658 g (Including brackets) |