Page View 2791 |
Product Information : |
|
Product Name: |
|
GF series |
|
Product Category: |
|
เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
|
Product Sub-Category: |
|
Counter / Timer (Counter & Timer)
|
Brand: |
|
Hanyoung |
Product Type : |
|
สินค้า, ผลิตภัณฑ์
|
|
|
|
|
- Counter/Timer - Set up digit of decimal points - Selection of voltage/non-voltage inputs - Timer range 16 kinds (10/60hexadecimal digits each 8 kinds)
Suffix code
Model |
Code |
Information |
GF4- |
|
|
|
|
Digital counter / Timer (48 X 48 ?) |
Type |
P |
|
|
|
Pre-set counter |
T |
|
|
|
Total counter |
Displayable digits |
4 |
|
|
4 digits (9999) |
Setting stage |
0 |
|
None (total counter) |
1 |
|
1st stage setting (Preset counter) |
Terminal structure |
N |
Terminal |
S |
8 pin structure (suitable for 8 pin socket) |
Model |
Code |
Information |
GF7- |
|
|
|
|
digital counter / Timer (72 X 72 ?) |
Type |
P |
|
|
|
Pre-set counter |
T |
|
|
|
Total counter |
Displayable digits |
4 |
|
|
4 digits (9999) |
6 |
|
|
6 digits (999999) |
Setting stage |
1 |
|
1st stage setting |
2 |
|
2nd stage setting |
0 |
|
Total counter |
Pre-scale function |
E |
Pre-scale function built in (Preset counter) |
N |
No Pre-scale (Total counter) |
Specification
Model |
GF4-P |
GF4-T |
Appearance(mm) |
|
|
In Timer function |
Repeat accuracy |
±0.01 % ± 0.05 % second Max. (Power supply start) |
± 0.005 % ± 0.003 % second Max. (Reset start) |
Ratio to set value |
|
Variation due to voltage change |
Variation due to temperature change |
Insulation resistance |
100 MΩ Min. (at 500 V d.c) (between current - carrying terminal and exposed noncurrent - carrying metal parts, between power supply circuit and control output circuit) |
Dielectric strength |
2,000 V a.c 50 / 60 Hz for 1 minute (between current - carrying terminal and exposed noncurrent - carrying metal parts, between power supply circuit and control output circuit) |
Noise immunity |
Square wave noise by simulator AC : ± 2 kV (between power supply terminal board) ± 500 V (between input terminal) |
Vibration |
Mechanical durability : 10 to 55 Hz : 0.75 mm double amplitude Malfunction durability : 10 to 55 Hz : 0.5 mm double amplitude |
Shock |
Mechanical durability : 300 m/s² (approx. 30 G) Malfunction durability : 100 m/s² (approx. 10 G) |
Life expectancy |
Mechanical : 10,000,000 operations Min. Electrical : 100,000 operations Min. (250 V a.c 3 A) |
Weight |
GF4 - P : 184 gms, GF4 - T : 168 gms (with adaptor), GF4 - P41S : 100 gms |
Power supply |
100 - 240 V a.c 50 - 60 Hz |
Power consumption |
GF4 - T : 4.8 V A, GF4 - P : 6.2 V A (240 V a.c 60 Hz) |
Reset / Inhibit |
Reset by power OFF : Min. power OFF time : 0.5 s External reset or inhibit : Min. reset input signal width : 0.02 s |
Control output |
SPDT : 250 V a.c 3 A cosØ = 1(resistive load) Open collector : 30 V d.c Max. 100 mA Max. |
Ambient temperature |
Operating : -10 °C to 55 °C |
Humidity |
35 to 85 % R.H. |
Model |
GF7-P |
GF7-T |
Appearance(mm) |
|
|
72(W) x 72(H) x 127.5(D) mm |
Sort |
Freeset |
Display |
Display method |
7 Segment LED , LED Height : 10mm |
Stage of freeset |
1 stage, 2stage |
- |
Display digit |
4 digits, 6digits |
6digits |
Max. Counting speed |
30 / 1K / 3K / 5Kcps |
Counting input |
contact, Non - contact |
Reset |
External reset : Min. input signal width 0.02sec(contact, Non-contact input ) Power reset : Min. power opening time 0.5sec |
Inhibit input |
Voltage input ( d.c input ) [H] level 5 ~ 30 V d.c, [L] level 0 ~ 2 V d.c ( input resistance Approx. 4.7 kΩ) |
Memory protection |
Semi-permanent |
Power voltage |
100 ~ 240V a.c ( 50 / 60Hz ) |
Power consumption |
Approx. 5V A ( 220V a.c 60Hz ) |
Sensor voltage |
12V d.c 50mA Max |
Control output |
Contact output : 1c 250V a.c 3 A / Non - contact output : 30V d.c, 100mA Max |
Insulation resistance |
Min, M? ( At 500V d.c ) part of conduction terminal and exposured non-electrify metal part |
Dielectric strength |
2000V a.c50 / 60Hz for 1minute ( Between + and - charging terminals ) |
Vibration |
Malfunction |
2 - 55Hz, X, Y, Z, Each direction for 10 minutes |
Durability |
10 - 55Hz, 0.76mm, X, Y, Z Each direction for 2 hours |
Shock |
Malfunction |
100 m/s² 6 positions, Each 3 times |
Durability |
300 m/s² 6 positions, Each 3 times |
Life |
Mechanical |
10 millions operations Min ( Relay type ) |
Electrical |
0.3 million operation Min. ( Relay type ) |
Ambient temperature and humidity |
0 ~ 50 °C(32 ~ 122 °F)?35 ~ 80 % R.H. (No icing) |
|
|
|
|
|
|
|
|