วิชา อินทนาคม
ผจก.
0897725584
[email protected]
ระบบควบคุมการปรับตัว สำหรับการใช้งานความดัน (STP)
ระบบควบคุมการปรับตัวสำหรับการใช้งานความดัน (STP) Adaptive control system for pressure applications (STP)
Last Update : 21/12/2016 09:13:15
3-way mixing globe valve
Brand : CONTROLLI
Last Update : 10:39:34 20/02/2017
RCF-230D is a thermostat for controlling heating and/or cooling in a room via on/off outputs. It also has a function for three-speed fan control (for fan-coil).
Brand : REGIN
Model : RCF-230D
RCF-230D Room thermostat for fan-coil applications with on/off outputs. Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan speed are set using the buttons on the front.
Last Update : 09:13:34 18/02/2017

Page View  6432  
Product Information :

Product Name:  
GTVS/GTRS 2- and 3-way flanged valve


Product Category:   เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
Product Sub-Category:   REGIN,VALVE & ACTUATORS, เครื่องจักร อุปกรณ์ เครื่องมือกล
Brand:   REGIN 
Product Type :   เครื่องมือ, เครื่องจักรและอุปกรณ์ 
     
 

GTVS/GTRS
2- and 3-way flanged valve
• Size DN32–150
• Kvs value 16–310
• Differential pressure 0.12–1.3 MPa
Control valves intended for use in heating and ventilation
systems, suitable for cold and hot water, glycol-mixed
water or steam.
• Pressure rating PN16
• Media temperature -5...+120°C
Function
GTVS:
The valve is open when the stem is at its lower position
and closed when the stem is at its highest position.
GTRS:
As the stem is at its lower position, flow-through between
ports A and AB is entirely open (and closed between
ports B and AB). As the stem is at its highest position,
flow-through between ports B and AB is entirely open
(and closed between ports A and AB).
Actuators
The valves are intended to be used together with
actuators of the type RVA... The OVA-F1 adapter kit is
factory mounted on models with DN32-40 and OVA-F2
is mounted on models with DN50-150.
Installation
The valves are to be mounted according to the flow
direction arrows on the valve.
The 2-way valve is to be mounted with port A as intake
and port AB as return (flow direction A in, AB out) to
ensure tight closure and prevent noise when closing.
The 3-way valve is of mixing type and should be mounted
at the mixing point.
Make sure to mount the 3-way valve so that correct flow
directions are obtained.
Material
Body in cast iron and stem in stainless steel. Plug and seat
in gunmetal. Self-adjusting PTFE packing box and O-rings
in Viton.
Control of refrigerants
The valves can be used with different refrigerants. In this
case, a special type of packing box must be mounted.
Contact Regin for more information.

2-way Connection Kvs Max diff. pressure
GTVS32-16 DN32 16 1.3 MPa
GTVS40-27 DN40 27 0.8 MPa
GTVS50-39 DN50 39 1.0 MPa
GTVS65-63 DN65 63 0.6 MPa
GTVS80-100 DN80 100 0.4 MPa
GTVS100-160 DN100 160 0.25 MPa
GTVS125-215 DN125 215 0.17 MPa
GTVS150-310 DN150 310 0.12 MPa

เอกสารแนบ
 

© 2000-2008 CopyRight by HVAC SQUARE Co.,Ltd.
Tel. 020654393 , 0897725584  Fax. 021906418  Website. http://www.hvac.co.th
disclaimer | privacy | contact us 

  Sale Login Warehouse Login Driver Login