Specifications
Technology : RF Admittance.
Calibration : None (for most applications).
Modes Of Operation : High and Low Level.
Repeatability : 2 mm (0.08 inch) conductive liquids.
Response Time : Less than one second.
Ambient Electronic Temperature : -40 to 70°C (-40 to 158°F) FM, FMc
Storage Temperature : -40 to 85°C (-40 to 185°F).
Indicators : LEDs: Green Power, Red Relay 1.
Time Delay : 0-60 seconds, forward or reverse-acting.
Supply Voltage : 19-250 VAC 18-200 VDC Auto-detecting without jumpers.
Power Consumption : 2 watts maximum.
Relay Contacts : DPDT dry contacts at 5A, 120Vac.
Maximum Contact Load : 5A/30 VDC 5A/250 VAC
Maximum Switching Capacity : 2000 VA/150 Watt.
Minimum Contact Load (DC) : 100 mA/12 VDC 0 -200 mA / 12 VDC (Optional)
Housing : Powder-Coated aluminum with two cable entries.
Cable Entry : M20 x 1.5 ¾-inch NPT
Ingress Protection : IP66 NEMA 4X
Approvals : Remote Explosion-proof for Class I, Division 1, Groups A, B, C, and D; Dust-Ignition proof for Class II, III, Division 1, Groups E, F, and G; Non-incendiary for Class I, Division 2, Groups A, B, C, & D; Suitable for Class II, III, Division 2, Groups F & G hazardous outdoor Type 4, 4X, IP66 (classified) locations with Intrinsically Safe connections to Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G hazardous (classified) locations in accordance with Control Drawing 420-0004-181-CD.
|