Technical Conversion Table
เพื่ออำนวยความสะดวกให้กับเพื่อนๆ เราขอนำเอา Conversion Table ของหน่วยที่ใช้งานอยู่เป็นประจำ ในงานด้าน Pneumatic หรือ Industrial Blower มาฝาก
Last Update : 01/07/2012 00:38:05
Bevel Gear Box
Brand : Makishinko
Model : SB, TB, FB
Last Update : 18:43:08 17/03/2024
AMGP-01NS Oil Lubrication Pump
Brand : Aryung
Model : Model AMGP-01NS
AMGP-01NS Division : Auto Oil Pump TYPE : AMGP-01NS
Last Update : 18:42:41 17/03/2024
Sirocco Blower Single Port Series
Brand : Nitco
Model : CY063, CY076, CY100, CY125, CY127
Last Update : 18:42:10 17/03/2024
Multi-Spindle Head S-160
Brand : Miyakawa
Model : S-160
S-160? (2?????19mm?160mm?) ?????(19mm-160mm)???????2???6?????????????????
Last Update : 18:41:45 17/03/2024
Air Shaft
Brand : Nitco
Model : Nitco
Last Update : 18:41:03 17/03/2024

Page View  2208  
Product Information :

Product Name:  
LT1


Product Category:   เครื่องจักร, อุปกรณ์เกี่ยวกับเครื่องจักร, เครื่องมือกล
Product Sub-Category:   Counter / Timer (Timer)
Brand:   Hanyoung 
Product Type :   สินค้า, ผลิตภัณฑ์ 
     
 

- Compact size LCD indicating total counter 
- Battery built in so external power is not needed 
- Reusing possible by replacing to the new battery 
- Long battery life due to the less power consumption 
- Non-voltage input or voltage input 
- IP66 protective structure(front side)


Suffix code

Model Code Information
LT1- Compact LCD display total Timer (dimension : DIN 48 X 24 ?)
Input signal   Non voltage input (no indication)
F Voltage input (24 - 240 V AC, 6 - 240 V DC)

Specification

Model LT1 LT1-F
Input method Non voltage input Voltage input(free voltage)
Power No power(battery built in, replacing possible)
Product size 48(W) x 24(H) mm
Operation method only for adding
Input Condition Remaining voltage when disconnected : Max 0.7 V
Max impedance when disconnected : Max 10 kΩ
Min impedance when opened : Min 1 MΩ
High : (24 - 240) V a.c / (6 - 240) V d.c
Low : (0 - 2) V a.c / d.c
Reset Input method non voltage input
Min signal range Min. 20 ms
Battery life more than 10 years(approx. 25 °C)
External setting switch *SW1, *SW2 *SW1
External connection terminal block(4 pins)
Indication method LCD 7 segment reflection type, alphabet height 8.7 mm black
Insulation resistance min 100 MΩ(500 V d.c mega standard, between the electric conduction part and exposed non-charging metal part)
Dielectric strength 2000 V a.c
(50/60 Hz for 1 min, between the electric conduction part and exposed non-charging metal part)
Vibration Vibration
resistance
double amplitude each to X, Y and Z direction for 2 hours
Malfunction double amplitude each to X, Y, Z direction for 10 min
Shock Shock resistance each X, Y and Z direction for 3 times
Malfunction
Ambient temperature -10 °C ~ 55 °C (with no icing and dew condensation)
Storage temperature -25 °C ~ 65 °C (with no icing and dew condensation)
Ambient humidity (35 ~ 85) % R.H.
Protective structure IP66
*SW1 : internal battery and front reset key setting switch *SW2 : time range setting switch *SW3 : counting speed setting switch


 

© 2000-2008 CopyRight by Nitco Plus
Tel. 02-226-5667-8  Fax. 02-224-8071  Website. www.nitcoplus.com