Model 430 Four Conductors, 2@4amps, 2@30amps
|
|
|
Disconnects included (4 sm., 4 lg.) Boot Kit available Available with stainless steel ball bearing (430-SS) |
Mercotac model 430 is ideal for heated roller applications, where connecting to senstive thermocouple signals and simultaneously powering the heater are required. |
|
|
Model No. |
Terminals |
Voltage AC/DC |
Amp Rating @240VAC |
Max. Freq. MHz |
Contact Resistance |
Max. RPM |
Temp Max. F (C) / Min. F (C) |
Rotation Torque (gm-cm) |
Circuit Separation |
430 |
4 |
0-250 |
2@4/2@30 |
100 |
<1m
|
|
|
1200 |
140 (60) /-20(-29) |
400 |
>25M
|
|
|
430-SS |
4 |
0-250 |
2@4/2@30 |
100 |
<1m
|
|
|
1200 |
140 (60) /-20(-29) |
400 |
>25M
|
|
|
"SS" designator indicates stainless steel ball bearing (recommended for wet or corrosive environments)
Model 430 Accessories |
|
|
50431 Plug Assembly 12 in. wires 14 AWG & 18 AWG Suitable for up to 20 Amps |
50430 Plug Kit - No wires, terminals for wire gauges 20 - 16 AWG & 16 - 14 AWG Suitable for up to 20 Amps Also order 5030-T |
|
|
57430 Boot Kit for dust or splash protection IP51 |
55251 Terminal 16 - 14 AWG (qty. 2 included) |
|
|
5030-T Plug Terminal Crimping Tool For Use With 50430 Kit |
55250 16 - 14 AWG (qty. 2 included) |
|
|
|
55110 22 - 18 AWG (qty. 4 included) |
|
Terminals for other wire gauges available. (22-18 AWG and 12-10 AWG)
|
|
Model 430 Standard Wire Connections |
Model 430 Wire Connections With Optional Boot |
|
Model 430 Suggested Mounting Methods |
Model 430 is typically mounted by either the black body or the white plastic bushing on either end using a set screw. When mounting horizontally, mount the Mercotac so the body of the connector rotates. |
|
Typical Body Mount Hole Dimensions
|
MODEL |
HOLE DIAMETER (Ø) * |
DEPTH |
430, et al |
1.248" (31.70) |
.80" (20) |
|
|
|
Typical Bushing Mount Hole Dimensions
|
430, et al |
.625" (15.88) |
.40" (10) |
With Plug Connector |
.625" (15.88) |
1.40" (36) |
*Inch (mm) Tolerance Ø |
+.001" (+.025) |
|
|
|
-.000" (-.000) |
|
|
|
|
Installation Notes:
- the up arrow should not point below horizontal
- do not solder to or bend connector tabs
- avoid lateral forces and mechanical loads (overly stiff or tight wires)
- do not rigid mount both ends of connector
- limit mounting eccentricity (runout / wobble) to .005" (.13mm)
- provide overload protection within the circuit
- avoid vibration and bumping motions
|
สนใจติดต่อขอรายละเอียดเพิ่มเติมได้ที่
บริษัท น่ำแซอินเตอร์เทรดดิ้ง จำกัด
Tel: 02-223-2271-3
Fax: 02-225-5546
E-mail: [email protected]
Website: www.namsae.com
Facebook: www.facebook.com/namsaefanpage
Line: @namsae
Instagram: namsae_official |